BK-GS6060 | Grating Spectrophotometer








Key Features


Product Description

Specifications


Model numberBK-GS6060
Optical geometryReflect: di: 8° | de: 8° (diffused illumination: 8º viewing angle)

 SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;

Conforms to:

ASTM D1003
CIE No.15
GB/T 3978
GB 2893
GB/T 18833
ISO 7724/1
ASTM E1164
DIN 5033 Part 7
Integrating sphere sizeΦ154mm
Light source360 nm to 780 nm, combined LED light
400 nm cut-off light source
420 nm cut-off light source
UV Lamp
Spectrophotometric modeConcave grating
Sensor256 x 256 pixel dual array CMOS image sensor
Wavelength range360 nm -780 nm
Wavelength interval10 nm
Semi-band width10 nm
Measured reflectance range0-200%
Measuring apertureReflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm;  
Specular componentReflectance: SCI & SCE
Transmittance: SCI & SCE
Colour spaceCIE LAB
, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN
Colour difference formulaΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1) , ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other colourimetric index WI (ASTM E313, CIE/ISO, AATCC, Hunter,

YI (ASTM D1925, ASTM 313),TI (ASTM E313, CIE/ISO),

MI (Metamerism Index), Staining Fastness,

Color Fastness, Color Strength, Opacity,

Gardner Index, Pt-Co Index, 555 Index
Observer angle2°/10°
IlluminantD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed dataSpectrogram/Values
Samples Chromaticity Values
 Color Difference Values/Graph
PASS/FAIL Result
Color Offset
Measuring timeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)

Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

                                    Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)

Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument errorΦ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles)
Illuminant life span5 years or more than 3 million measurements
Display7-inch TFT color LCD, Capacitive Touch Screen
Data portUSB & Bluetooth
Data Storage
Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE)
Operating environment0~40℃ | 0~85% RH (non-condensing) | Altitude < 2000 m
Standard accessories
  • White and black calibration board
  • Checking green board
  •  Sample holder
  • ∮4 mm: ∮8 mm: ∮15 mm: ∮25.4 mm aperture
  • Power adapter
  • USB cable
  • User guide
  • PC software
Optional accessories
  • Micro printer
  • Transmissive Test Clamp Component
Electrical requirementsPower adapter input: 230VAC 50/60 Hz
Power adapter output: 24 VDC: 3A
Instrument dimensions (L x W x H)370 mm x 300 mm x 200 mm
Weight9.6 Kg